The Lead - Testing, Commissioning & Quality will establish and lead the Quality Assurance, Testing, Commissioning and Operational Readiness function for the Data Center business.
The incumbent will be responsible for developing commissioning strategies, quality systems, integrated testing procedures and operational readiness programs to ensure successful project delivery and customer acceptance.
The role will work closely with Design, Engineering, Construction, Operations, OEMs and Customers to deliver mission-critical facilities meeting Tier III / Tier IV requirements.
Role & responsibilities
1. Commissioning Strategy & Leadership
- Establish commissioning philosophy and procedures for all Data Center projects.
- Develop Level 1 to Level 5 commissioning protocols.
- Define Integrated Systems Testing (IST) methodology.
- Lead commissioning planning from design stage through handover.
- Establish Operational Readiness and Day-One readiness processes.
1. Electrical Systems Commissioning
Lead team of commissioning engineers for :
- 400kV / 220kV / 132kV Receiving Stations
- GIS/AIS Substations
- Transformers
- MV Switchgear
- LV Switchgear
- UPS Systems
- Static Transfer Switches
- Busway Systems
- Generator Systems
- Synchronization Systems
- Protection Systems
- SCADA Systems
1. Mechanical Systems Commissioning
Oversee commissioning of:
- Chilled Water Systems
- CRAH Units
- CRAC Units
- Cooling Towers
- Pumps
- Thermal Containment Systems
- Fuel Systems
- Water Treatment Plants
- Ensure proper integration with electrical infrastructure.
1. Integrated Systems Testing (IST)
- Develop complete IST protocols.
- Validate redundancy architecture.
- Verify failover and recovery sequences.
- Conduct black building tests.
- Conduct utility outage simulations.
- Conduct UPS and generator transition testing.
- Lead customer witness testing.
5. Quality Management Establish Quality Management Systems covering:
Coordinate FATs, inspections and commissioning support.
7. Customer Interface
Represent Transrail during
- Customer audits
- Witness testing
- Technical reviews
- Readiness assessments
- Final acceptance testing
8. Team Building
Phase 1
- Electrical Commissioning Manager
- Mechanical Commissioning Manager
- QA/QC Manager
Phase 2
- IST Specialists
- Documentation Leads
9. Process Development
Develop
- Commissioning SOPs
- Quality Manuals
- FAT/SAT Templates
- Inspection Checklists
- Operational Readiness Framework
- Lessons Learned Database
Preferred candidate profile
- B.E. / B. Tech in Electrical/Mechanical Engineering (Mandatory) with minimum 10-15 years of experience.
- Minimum 5 years in Data Center commissioning.
- Additional certifications in Data centre Commissioning, Quality or Reliability preferred.
- Experience with hyperscale or colocation facilities on commissioning and quality assurance.
- Proven experience in mission-critical infrastructure.