HVDC/ VSC System Expert- Substation/HVDC (Olpad)

HVDC/ VSC System Expert- Substation/HVDC (Olpad)

20 Aug
|
Aecom
|
Olpad

20 Aug

Aecom

Olpad

Job Description

Position Overview:

Provide specialist technical oversight for ±500 kV VSC-HVDC terminal stations, including converter technology, AC/DC system interfaces, converter transformers, valves, reactors, filters, control systems, protection systems, and overall system integration to ensure compliance with project requirements and industry standards.

Key Responsibilities:

- Review overall HVDC system architecture, design criteria, technical specifications, and interface requirements across the complete VSC-HVDC scheme.
- Review OEM design documentation for VSC converters, converter transformers, valves, DC equipment, AC equipment, and associated auxiliary systems.
- Assess the design and performance of AC/DC filters, smoothing reactors, harmonic filters, reactive power compensation systems, and associated equipment.
- Review station control, HVDC control, valve control, protection systems, monitoring systems, and sequence-of-events functionality.
- Evaluate operating philosophies, power control functions, voltage control strategies, reactive power control, black-start capability, and system recovery arrangements.
- Review protection coordination between the HVDC system, AC substations, converter stations, grid protection systems, SCADA, and telecommunication networks.
- Assess and review system studies including load flow, short-circuit, harmonic performance, insulation coordination, overvoltage analysis, electromagnetic interference, and energetic performance studies.
- Verify technical interfaces between converter transformers, valves, cooling systems, control systems, communication systems, and station auxiliary equipment.
- Review OEM manufacturing processes, factory acceptance testing (FAT), installation procedures,



site acceptance testing (SAT), and commissioning methodologies.
- Participate in design reviews, engineering workshops, technical audits, risk assessments, and technical resolution meetings.
- Review control and protection settings, logic diagrams, interlocks, operational philosophies, and functional specifications.
- Witness and review factory and site testing activities where contractually required, ensuring compliance with approved procedures and performance requirements.
- Support technical issue resolution during installation, integration, testing, energization, and trial operation phases.
- Monitor subsystem testing, integrated system testing, station energization, and operational readiness activities.
- Identify technical risks, design gaps, performance concerns, and interface issues, providing mitigation recommendations and corrective actions.
- Review as-built documentation, operation and maintenance manuals, training materials, and handover documentation prior to project closeout.
- Coordinate with Substation, Protection & Control, SCADA, Telecommunications, and Grid Integration teams to ensure seamless interface management and system integration.

Principal Client-Facing Outputs

- HVDC Design Review and Technical Assurance Report.
- OEM Design and Documentation Review Comments.
- HVDC System Interface and Integration Assessment.
- Converter Control and Protection Review Report.
- Power System Study Review Memorandum.
- HVDC Technical Risk Register and Mitigation Plan.
- Factory and Site Testing Assessment Reports.
- Commissioning and Energization Readiness Assessment.
- Technical Compliance and Performance Verification Report.
- Final HVDC Technical Assurance and Handover Report.

📌 HVDC/ VSC System Expert- Substation/HVDC (Olpad)
🏢 Aecom
📍 Olpad

Reply to this offer

Impress this employer describing Your skills and abilities, fill out the form below and leave Your personal touch in the presentation letter.

Subscribe to this job alert:

Get the latest job offers by email for: hvdc/ vsc system expert- substation/hvdc (olpad) / olpad

Subscribe to this job alert:

Get the latest job offers by email for: hvdc/ vsc system expert- substation/hvdc (olpad) / olpad