17 Sep
|
Larsen u0026 Toubro-Vyoma
|
Pallavaram
17 Sep
Larsen u0026 Toubro-Vyoma
Pallavaram
1.
Job Purpose /n Lead protected, reliable and SLA-compliant operation of the 30 MW data center during the assigned shift. The role is accountable for real-time monitoring, maintenance coordination, incident command, change control, customer support and shift-team performance across electrical, mechanical, fire-life-safety, security and automation systems.
The Shift
Lead acts as the single operational owner on duty and ensures disciplined execution of SOPs, MOPs and EOPs, accurate escalation, and complete shift handover. /n 2. Role Scope and Critical Infrastructure /n /n
- Electrical: utility/GIS interface, transformers, MV/LT switchgear, bus ducts, DG systems, UPS, batteries, STS/ATS, PDUs/RPPs, earthing and lightning protection.
/n
- Mechanical: chillers, cooling towers or heat-rejection systems, pumps, PAHU/AHU/CRAH units, chilled-water network, valves, VFDs, ventilation, plumbing and water-treatment systems.
/n
- High-density cooling, where deployed: CDUs, primary and technology-cooling loops, liquid-cooling alarms, leak detection, pressure, flow and temperature monitoring.
/n
- Fire and life safety: FAS, VESDA, clean-agent/fire-suppression systems, hydrant/sprinkler systems, emergency exits and emergency response equipment.
/n
- Monitoring and security: BMS, EPMS, DCIM, WLD, CCTV, access control, public-address and related command-center systems.
/n
- Customer environments: white-space power and cooling availability, rack power provisioning, remote-hands coordination and approved customer activity support.
/n /n 3.
Key Accountabilities /n A.
Shift
Command and 24x7 Monitoring /n /n
- Assume formal charge of the facility at shift start, review open risks, alarms, impairments, ongoing work, capacity constraints and customer commitments.
/n
- Maintain continuous command-center oversight of BMS, EPMS, DCIM, FAS, VESDA, WLD, CCTV and access-control alarms; ensure each alarm is acknowledged, validated, recorded and closed or escalated.
/n
- Deploy shift engineers and technicians based on risk, permit status, workload and competency; maintain minimum required coverage across critical areas.
/n
- Conduct scheduled facility rounds and verify equipment health, operating parameters, redundancy status, housekeeping, safety conditions and abnormal indications.
/n
- Maintain a clear operating picture of available capacity, redundancy, equipment under maintenance, bypass conditions and temporarily impaired protection.
/n /n B. Incident, Emergency and Escalation Management /n /n
- Act as first incident commander for alarms, equipment trips, utility disturbances, cooling excursions, leaks, fire alarms, security events and customer-impacting conditions.
/n
- Execute the approved EOP, stabilize the facility, protect people and assets, preserve redundancy, and escalate through the defined communication matrix.
/n
- Open and manage incident tickets, maintain a timestamped event log, coordinate technical response, provide factual updates and drive restoration within agreed SLA/TAT.
/n
- Ensure preservation of evidence, event logs, trends and witness inputs; support preliminary incident reports and detailed RCA/corrective-action closure.
/n
- Initiate emergency services, OEM or management support in accordance with site procedures and authority limits.
/n /n C. Maintenance and Change Control /n /n
- Plan and control preventive, predictive,
condition-based and breakdown maintenance during the shift without compromising safety, redundancy or customer service.
/n
- Verify approved work order, risk assessment, method statement, permit-to-work, isolation/LOTO, rollback plan, test instruments, spares and competent manpower before work begins.
/n
- Lead pre-work briefing and post-work validation; confirm system normalization, alarm clearance, removal of temporary arrangements and closure of permits and change records.
/n
- Coordinate OEMs and vendors, verify attendance and workmanship, track observations, and escalate overdue maintenance, defects and repeat failures.
/n
- Raise and manage change requests for site work, configuration updates, maintenance and commissioning; stop work when controls are inadequate or conditions deviate from approval.
/n /n D. Capacity, Efficiency and Customer Delivery /n /n
- Monitor electrical and cooling loading, operating margins and redundancy; escalate threshold breaches and emerging capacity risks.
/n
- Track shift-level energy and water performance indicators, including PUE/WUE inputs, abnormal consumption and avoidable simultaneous or unloaded operation.
/n
- Coordinate approved power provisioning, energization, commissioning, capacity augmentation and customer delivery activities.
/n
- Manage customer calls, service requests, incident communications and remote-hands support within approved scope and access controls.
/n
- Protect customer confidentiality and ensure activities in white space are executed with authorization, escort, ESD controls and accurate closure records.
/n /n E. Safety, Compliance and Audit Readiness /n /n
- Enforce electrical, mechanical, work-at-height, hot-work, confined-space, lifting and chemical-safety controls applicable to activities during the shift.
/n
- Ensure permits, LOTO, PPE, toolbox talks, competency checks and emergency arrangements are in place; exercise stop-work authority for unsafe conditions.
/n
- Maintain readiness for statutory, customer and management audits; retain complete logs, checklists, test records, permits and maintenance evidence.
/n
- Follow site requirements for ISO management systems, environment, health and safety, security and applicable statutory interfaces; immediately report non-compliance.
/n
- Conduct or participate in emergency drills, post-drill reviews and action closure.
/n /n F. Team, Vendor and Shift Handover /n /n
- Brief, coach and assess shift personnel on assigned tasks, site procedures, emergency response and equipment operation.
/n
- Coordinate effectively with security, safety, IT/network, projects, customer delivery, facility management, OEMs and service partners.
/n
- Prepare daily, weekly and monthly operating inputs, including alarms, incidents, maintenance, capacity, efficiency, safety, risks, vendor performance and pending actions.
/n
- Complete a structured face-to-face handover covering open incidents, active permits, disabled alarms/interlocks, equipment out of service, temporary configurations, pending changes,
customer commitments and escalation status.
/n
- Ensure no critical action is transferred without named ownership, due time and acknowledgement by the incoming Shift Lead.
/n /n 4. Deliverables and Performance Measures /n Availability /n Continuous operation of critical infrastructure and protection of configured redundancy /n SLA/availability compliance; zero avoidable service-impacting error /n Alarm response /n Timely acknowledgement, validation, dispatch, escalation and closure /n Alarm response and closure within site-defined thresholds /n Incident control /n Safe stabilization, accurate communication, event logging and restoration /n Incident SLA/TAT; RCA and corrective actions closed on time /n Maintenance /n Controlled PM/BM execution with complete records and normalization /n PM compliance; overdue work and repeat defects minimized /n Change control /n Risk-assessed execution with approved MOP, rollback and post-checks /n No unauthorized change; change success and closure compliance /n Safety /n Permit, LOTO, PPE and work-control discipline /n Zero unsafe work acceptance; observations and actions closed /n Efficiency /n Monitoring of load, energy, water and operating optimization /n Accurate PUE/WUE inputs; abnormal variance escalated /n Handover /n Complete, factual and acknowledged transfer of operational status /n 100% shift log and handover checklist completion /n Team readiness /n Competent staffing, drills, coaching and procedure adherence /n Training/drill completion and competency gaps closed /n 5.
Decision
Rights and Escalation /n /n
- Stop any activity that presents an unacceptable safety, reliability, compliance or customer-impact risk.
/n
- Initiate approved EOPs and emergency escalation without delay when trigger conditions are met.
/n
- Defer or suspend maintenance/change work if redundancy, staffing, permits, tools, spares, weather, utility condition or facility state is unsuitable.
/n
- Call OEM/vendor support and internal escalation teams within the approved authority and contact matrix.
/n
- Escalate immediately when operating limits, service risk or recovery time exceed site-defined thresholds; do not normalize or conceal alarms without authorization.
/n /n 6.
Qualifications and Experience /n Education /n Diploma / BE / B.Tech in Electrical, Mechanical or equivalent engineering discipline. /n Experience /n 6-10 years of relevant critical-facility or data center operations and maintenance experience, including at least 2 years in shift coordination or team-lead responsibility. /n Technical Exposure /n Hands-on troubleshooting and maintenance exposure across UPS, batteries, DG, transformers, switchgear, PDU, chillers, PAHU/AHU/CRAH, pumps, fire systems and controls. /n Systems Exposure /n Working knowledge of BMS, EPMS, DCIM, FAS, VESDA, WLD, CCTV and access-control platforms. /n Process Exposure /n Experience with incident, problem, change, permit-to-work, LOTO, preventive maintenance, vendor management, customer calls and remote-hands services. /n Preferred Certifications /n CDCP/CDCS or equivalent data center certification; electrical authorization, safety, first-aid/fire-fighting or OEM training relevant to assigned duties. /n Communication /n Clear verbal and written communication, disciplined documentation, concise escalation and confident coordination with customers and vendors.
📌 Shift Lead - Data Center Operations (Pallavaram)
🏢 Larsen u0026 Toubro-Vyoma
📍 Pallavaram