Role & responsibilities
1. Commissioning Strategy & Leadership - - - - -
Establish commissioning philosophy and procedures for all Data Center projects.
Develop Level 1 to Level 5 commissioning protocols.
Define Integrated Systems Testing (IST) methodology.
Lead commissioning planning from design stage through handover.
Establish Operational Readiness and Day-One readiness processes.
2. Electrical Systems Commissioning
Lead team of commissioning engineers for : - - - - - - - - - - - -
400kV / 220kV / 132kV Receiving Stations
GIS/AIS Substations
Transformers
MV Switchgear
LV Switchgear
UPS Systems
Static Transfer Switches
Busway Systems
Generator Systems
Synchronization Systems
Protection Systems
SCADA Systems
3. Mechanical Systems Commissioning
Oversee commissioning of: - - - - - - - - -
Chilled Water Systems
CRAH Units
CRAC Units
Cooling Towers
Pumps
Thermal Containment Systems
Fuel Systems
Water Treatment Plants
Ensure proper integration with electrical infrastructure.
4. Integrated Systems Testing (IST) - - - - - - -
Develop complete IST protocols.
Validate redundancy architecture.
Verify failover and recovery sequences.
Conduct black building tests.
Conduct utility outage simulations.
Conduct UPS and generator transition testing.
Lead customer witness testing.
5. Quality Management
Establish Quality Management Systems covering:
- - - - - - -
Design Quality Reviews
Vendor Quality Audits
FAT Procedures
SAT Procedures
Installation Quality
Documentation Quality
Handover Quality
Develop project quality plans and audit systems.
6. OEM & Vendor Coordination
Coordinate FATs, inspections and commissioning support.
7. Customer Interface
Represent Transrail during: - - - - -
Customer audits
Witness testing
Technical reviews
Readiness assessments
Final acceptance testing
8. Team Building
Phase 1 - - -
Electrical Commissioning Manager
Mechanical Commissioning Manager
QA/QC Manager
Phase 2 - -
IST Specialists
Documentation Leads
9. Process Development
Develop: - - - - - -
Commissioning SOPs
Quality Manuals
FAT/SAT Templates
Inspection Checklists
Operational Readiness Framework
Lessons Learned Database
Preferred candidate profile
B.E. / B. Tech in Electrical/Mechanical Engineering (Mandatory) with minimum 1015
years of experience.
Minimum 5 years in Data Center commissioning.
Additional certifications in Data centre Commissioning, Quality or Reliability preferred.
Experience with hyperscale or colocation facilities on commissioning and quality
assurance.
Proven experience in mission-critical infrastructure.
Interested candidates can reply on
[email protected]
📌 Lead - Testing, Commissioning & Quality (Data Centers) (Mumbai)
🏢 Adler Talent Solutions
📍 Mumbai