Refrigeration Compliance - Implementation Engineer (Chennai)

Refrigeration Compliance - Implementation Engineer (Chennai)

29 Oct
|
Facilio
|
Chennai

29 Oct

Facilio

Chennai

Refrigeration Compliance SME — Solution Architect/ Implementation Engineer The Role

Facilio is hiring a Refrigeration SME to be the primary domain expert and service delivery lead across our food-retail customer engagements. You will lead the customer success and remote monitoring service delivery efforts for the food retail customers focussed on end-to-end monitoring and failure prediction of refrigeration systems and serve as trusted advisor to customers' engineering and operations teams — owing full life cycle of the customer engagement starting from first BRD workshop through post-go-live optimisation.

Every SOW we deliver to a food retailer contains a refrigeration layer requiring specialist judgment. You will own that layer with authority — and shape how Facilio solves it at scale.

What You'll Do

Solution Architecture

- Design end-to-end refrigeration monitoring & compliance architectures for multi-site retail deployments
- Define connectivity strategy: controller compatibility, agent topology, data ingestion design
- Architect asset hierarchies, rack-to-case mappings, refrigerant libraries, and commissioning standards

Customer Engagement

- Lead refrigeration discovery workshops and BRD sign-off with engineering & FM stakeholders
- Own the refrigeration solution design section across proposals, BRDs, and SOWs
- Deliver advisory through UAT, go-live, and post-go-live optimisation phases

FDD & Alarm Intelligence

- Define FDD rule strategy — translating customer set points into prioritised monitoring programmes
- Design rules for iced cases, superheat deviations, slow leaks, valve anomalies, sensor faults
- Advise on alarm severity frameworks, noise-reduction, and escalation paths post go-live

Presales & Product Influence

- Scope refrigeration workstreams in customer proposals — controller compatibility,



FDD complexity, regulatory obligations
- Represent the customer voice in product discussions; shape roadmap with domain-led requirements
- Build reusable artefacts: reference architectures, FDD rule libraries, compliance playbooks

Regulatory Advisory

- Lead EPA 608 and AIM Act compliance design: event types, leak rate logic, inspection scheduling
- Guide customers migrating from Accruent/Verisae and similar legacy CMMS platforms
- Advise on HFC phase-down implications and audit-readiness under evolving refrigerant regulations

What You Bring

Refrigeration Systems

- System architecture: parallel compression rack systems, CO2 transcritical, secondary loop, and DX systems — and how architecture choices affect monitoring strategy
- Controller hierarchy: store controller (E2 or equivalent) → rack controllers → case controllers → sensors; ability to read full point lists and map I/O to asset telemetry
- Emerson/Copeland E2/E3 (required); Danfoss AK-SC255 / AK-CC series (preferred); iLon, RDM, Carel, Modbus, BACnet, LON integration experience
- Temperature zone expertise: low-temp frozen (−10°F to 0°F), medium-temp meat/dairy (25–35°F), high-temp produce (35–45°F) — and how zone-specific set points anchor FDD rule design
- Defrost cycle types — electric, hot gas, off-cycle — and how defrost recovery patterns surface in telemetry as iced-case or false-alarm signals
- Refrigerant thermodynamics in practice:



superheat/subcooling management, EEV control, floating suction pressure, condenser head pressure optimisation
- Refrigerant types across the transition landscape: R-404A phase-down, HFO alternatives (R-448A, R-449A), natural refrigerants (R-744 CO2, R-290 propane) — and their GWP and system design implications

Regulatory & Compliance

- EPA Section 608 in depth: annualised leak rate calculation (refrigerant added ÷ full charge), inspection frequency thresholds pre- and post-AIM Act, 3-year recordkeeping obligations, and technician certification by appliance type
- AIM Act HFC allocation schedule and its practical impact on asset retrofit decisions, refrigerant procurement, and compliance programme design for large portfolios
- Familiarity with CARB SLCP regulations for accounts with California footprint; understanding of when EPA mandatory retrofit or retirement obligations are triggered
- Prior experience operating or implementing a refrigerant tracking system — Accruent/Verisae, ServiceChannel, or comparable CMMS with compliance module

Consulting & Delivery

- 3–5 years in solutions consulting, SA, or implementation — CMMS / connected buildings / IoT preferred
- Led discovery workshops and produced solution architecture artefacts for enterprise customers
- Comfortable scoping commercially, assessing risk, and holding a robust technical opinion
- Full lifecycle experience: BRD → delivery → UAT → post-go-live ROI/Value Add advisory

Industry Background

- Experience in commercial refrigeration — as a controls specialist, field engineer, or FM/energy consultant at a multi-site food retailer
- Preferred: direct experience at a grocery chain (20+ stores), refrigeration OEM, or connected refrigeration SaaS

📌 Refrigeration Compliance - Implementation Engineer (Chennai)
🏢 Facilio
📍 Chennai

Reply to this offer

Impress this employer describing Your skills and abilities, fill out the form below and leave Your personal touch in the presentation letter.

Subscribe to this job alert:

Get the latest job offers by email for: refrigeration compliance - implementation engineer (chennai) / chennai

Subscribe to this job alert: