Role & responsibilities
Site Execution & Technical Supervision
- End-to-End Electrical Oversight. Monitor and manage on-site installation of electrical systems ranging from HT (up to 220kV substations) to MV and LV distribution networks. [1]
- Critical Equipment Coordination. Track delivery, installation, and hook-up of specialized data center equipment including transformers, HT/LT switchgear, DG sets, UPS systems, batteries, PDUs, busducts, and earthing/lightning protection. [1, 2]
- Design & Drawing Compliance. Review shop drawings, technical submittals, and method statements to ensure site execution matches approved "Good for Construction" (GFC) drawings. [1, 2, 3]
2. Project Controls, Tracking & Vendor Management
- Vendor & Contractor Monitoring. Conduct day-to-day tracking of MEP contractors and OEM vendors to prevent schedule slippage on long-lead electrical items. [1, 2]
- Documentation & Registers. Maintain project logs in the Common Data Environment (CDE), including Requests for Information (RFIs), material submittals, change requests, and non-conformance reports (NCRs). [1, 2]
- Progress Reporting. Prepare daily, weekly, and monthly progress reports, record minutes of client/contractor meetings, and escalate site bottlenecks to the Electrical Project Manager. [1, 2]
3. Quality,
Safety & Commissioning (QA/QC & Cx)
- Quality Assurance. Enforce strict QA/QC checklists during cable laying, termination, panel installation, and testing.
- Testing & Commissioning (IST). Support Factory Acceptance Tests (FAT), Site Acceptance Tests (SAT), pre-commissioning checks, and Integrated Systems Testing (IST) up to final energization.
- HSE Compliance. Ensure contractors adhere to electrical safety protocols, Lockout/Tagout (LOTO) procedures, and site Health, Safety, and Environment (HSE) standards.
- Handover & Billing Support. Verify contractor measurements for bill certification, resolve snag/punch-list items, and compile closeout documentation such as O&M; manuals, warranties, and as-built drawings. [1, 2, 3, 4, 5]
Core Skills & Competencies
- Technical Knowledge. Deep understanding of redundant data center topologies (Tier III / Tier IV, N+1, 2N configurations) and Indian Electricity Rules / IEC standards.
- Software Proficiency. Familiarity with AutoCAD, Navisworks (for clash detection review), MS Project/Primavera basics, and MS Excel.
- Soft Skills. Strong stakeholder management, assertive contractor coordination, and transparent written reporting for client leadership.