17 Nov
|
Bindal Stainless Sirmaur
|
Paonta Sahib
17 Nov
Bindal Stainless Sirmaur
Paonta Sahib
EXECUTIVE
Vice President (VP) Central Maintenance Department
(Electrical & Mechanical)
Company: Bharat Green Recycling & Renewables LimitedPlant Location: Paonta Sahib, Himachal PradeshCorporate Head Office: New DelhiIndustry: Stainless Steel & Heavy ManufacturingDepartment: Central Maintenance (Mech., Elec., Auto. & Utilities)Reporting To: Director / Chief Executive Officer / Plant HeadEmployment Type: Full-Time, On-SiteProduct Portfolio: Stainless Steel Flats, Coils & Pipes
Position Overview
Bharat Green Recycling & Renewables Limited is seeking a seasoned, strategic, and hands-on Vice President (VP) Central Maintenance Department to lead all integrated mechanical, electrical, instrumentation, automation, and utility maintenance operations across our stainless steel manufacturing complex at Paonta Sahib, Himachal Pradesh.
The VP Central Maintenance will hold end-to-end ownership of plant asset reliability, zero-downtime operational readiness, energy and utility efficiency, and CAPEX equipment erection/commissioning across the Steel Melting Shop (Induction Furnaces & AOD Converter), Continuous Casting Machine (CCM), Rolling Mills, Tube/Pipe Mills, Pickling/Finishing Lines, and the 220 kV Main Power Step-down Substation (MPSS). A core strategic mandate of this executive role is to institutionalize a 100% system-driven maintenance culturereplacing individual/tribal memory with standardized Preventive & Predictive Maintenance (PM/PdM), plant-wide as-built engineering mapping, equipment history cards, and in office visual work instructions.
Key Responsibilities
1. Integrated Plant Reliability & Maintenance Strategy
- Central Maintenance Governance: Formulate and execute a unified Central Maintenance Strategy covering Mechanical, Electrical, Automation, and Plant Utilities to achieve maximum Overall Equipment Effectiveness (OEE) and plant availability.
- Failure Elimination: Eliminate chronic equipment breakdowns through structured Root Cause Analysis (RCA), Failure Mode and Effects Analysis (FMEA), and Corrective & Preventive Action (CAPA) governance.
- Shutdown & Turnaround Execution: Plan, schedule, and lead periodic Major Plant Shutdowns and Turnarounds, ensuring 100% on-time execution within approved shutdown budgets.
2. Steel Melting Shop (SMS) Maintenance (Mechanical & Electrical)
- Melting & Refining Asset Uptime: Ensure maximum equipment reliability and minimal tap-to-tap delays across primary steelmaking and refining units:
- Induction Furnaces (IF): Medium-frequency solid-state thyristor/IGBT power supplies, converter bridges, DC chokes, induction coil assemblies, hydraulic tilting cylinders, earth-leakage protection circuits, and closed-loop DM water cooling systems.
- AOD Converter: Converter vessel tilting drives and heavy-duty gearboxes, trunnion bearings, automated oxygen/argon/nitrogen gas-mixing manifolds, tuyere cooling, hood/fume extraction systems,
and process safety interlocks.
- Continuous Casting Machine (CCM) & Ladle Handling: Mold oscillation drives, withdrawal and straightening roll units, hydraulic shear systems, tundish cars, slide-gate hydraulics, and ladle turret mechanisms.
3. Rolling Mills, Tube/Pipe Mills & Heavy Material Handling
- Hot & Cold Rolling Mills: Direct mechanical and electrical upkeep of rolling mill stands, roll chocks, backup/work roll bearings, pinion stands, heavy-duty gearboxes, and synchronized multi-drive VFD systems.
- Tube/Pipe & Finishing Lines: Oversee maintenance of ERW/welded stainless steel pipe & tube mills, forming and sizing stands, high-frequency/TIG welders, straightening machines, hydro-testers, slitting lines, and pickling/annealing units.
- Heavy-Duty EOT Cranes: Maintain 100% safety and availability of hot metal ladle cranes, scrap charging magnet cranes, and coil/pipe handling cranes covering wire ropes, brake thrusters, gearboxes, crab assemblies, and wireless radio remote controls.
4. 220 kV Substation, Power Infrastructure & Plant Utilities
- 220 kV Switchyard & MPSS Operations: Supervise 24/7 safe operations of the 220 kV Main Power Step-down Substation (MPSS), power transformers, SF6 switchgear, busbars, CTs/PTs, numerical protection relays, and power quality/harmonic mitigation systems (STATCOM / SVC).
- Plant Utilities Management: Direct maintenance and reliability of critical plant utilities including the Air Separation Unit (ASU / Oxygen & Argon Plant), compressed air stations, cooling towers, Water Treatment Plants (WTP/ETP/STP), acid regeneration/neutralization systems, and fuel gas/oil networks.
- Energy Optimization: Drive aggressive reduction in Specific Power Consumption (kWh/MT) and utility losses across melting, rolling, and finishing operations.
5. Institutionalizing System-Driven Maintenance (Zero Man-Dependency)
- Complete As-Built Engineering Mapping: Establish and maintain updated plant-wide electrical Single Line Diagrams (SLDs), cable schedules, P&IDs; (Piping & Instrumentation Diagrams), hydraulic/pneumatic circuit drawings, and standardized alphanumeric wire/equipment tagging.
- Equipment History Cards: Enforce physical and ERP-based Equipment History Cards for all critical mechanical and electrical assets (transformers, breakers, furnaces, gearboxes, hydraulic power packs, pumps, and motors >15 kW).
- Condition-Based & Predictive Maintenance (PdM): Institutionalize infrared thermography, vibration analysis, tribology/lube oil analysis, transformer DGA/BDV testing,
ultrasonic thickness gauging, and motor meggering/PI schedules.
- Shop-Floor Visual Management: Mandate laminated SLD/P&ID; display boards, lubrication charts, emergency shock/safety charts, and step-by-step Standard Work Instructions (SWIs) at all substations, hydraulic rooms, operator pulpits, and MCCs.
6. Spare Parts Inventory, Budgeting & Central Workshop
- Maintenance Cost Governance: Optimize Maintenance OPEX and CAPEX budgets, strictly controlling spares consumption, external repair expenses, and contractor deployment costs.
- Scientific Spares Planning: Partner with Stores & Procurement to establish scientific Min-Max / Reorder Point (ROP) levels for critical insurance spares, bearings, seals, hydraulic valves, VFD cards, and thyristor modules, while liquidating non-moving inventory.
- Central Workshop Operations: Manage the in-house Machine & Fabrication Workshop (lathes, milling, boring, welding, dynamic balancing) to maximize internal refurbishment of rolls, shafts, chocks, and worn mechanical assemblies.
7. Statutory Compliance, Safety & Team Leadership
- Statutory Liaison: Serve as the principal technical authority for regulatory liaison with HPSEB / HPPTCL, Chief Electrical Inspector to Government (CEIG), Directorate of Factories & Boilers (IBR), and State Pollution Control authorities.
- Industrial Safety & LOTO: Enforce uncompromising adherence to Lockout/Tagout (LOTO), Permit-to-Work (PTW), working-at-height, confined space, and hot-work safety standards across all internal technicians and maintenance contractors.
- Capability Building: Lead, mentor, and upskill a multi-disciplinary engineering organization comprising DGMs, AGMs, Mechanical/Electrical/Automation Engineers, Shift In-charges, and technicians.
Candidate Profile & Qualifications
- Education: B.E. / B.Tech in Mechanical or Electrical Engineering from a recognized university. Post-Graduate qualification (M.Tech / MBA in Operations) is advantageous.
- Statutory Credentials: Valid Grade-A Electrical Supervisor Competency Certificate (EHV/Industrial) and/or working mastery of Indian Boiler Regulations (IBR) and factory safety statutes is strongly preferred.
- Experience: 2230 years of progressive industrial maintenance experience in heavy continuous-process manufacturing, with at least 710 years heading integrated Mechanical & Electrical maintenance at a VP / Chief Engineer / GM level.
- Industry Background: Mandatory leadership background in Integrated Steel Plants, Stainless Steel Manufacturing, Steel Melting Shops (Induction Furnaces, AOD, CCM), and Rolling/Tube Mills.
- Core Competencies: Proven track record managing 220 kV / 132 kV EHV substations, heavy metallurgical furnaces, high-pressure hydraulics, and automated rolling mills, with demonstrated success transitioning maintenance operations into structured, ERP-backed, system-driven frameworks.
📌 VP-Central Maintenance Department (E&M) (Paonta Sahib)
🏢 Bindal Stainless Sirmaur
📍 Paonta Sahib