19 Nov
|
Switchgear and Control Technics Private Limited(SCTPL)
|
Bengaluru
19 Nov
Switchgear and Control Technics Private Limited(SCTPL)
Bengaluru
Role Summary We are looking for an experienced Project Manager to lead the end-to-end execution of Supply, Installation, Testing Commissioning (SITC) projects for LV/MV electrical panels. The role owns projects from order receipt through drawing approval, manufacturing coordination with the plant, site installation, testing, commissioning and final handover. Hands-on experience in data centre projects is Beneficial, zas is a willingness to travel to and stay at project sites as required.
Key Responsibilities
• Project Planning Execution
• Prepare detailed project execution plans, schedules (MS Project / Primavera) and resource plans from the purchase order and technical specifications.
• Drive projects through the full SITC cycle – engineering, procurement, manufacturing, dispatch, installation, testing, commissioning and handover.
• Track progress against baseline schedule, cost and quality targets; publish regular progress reports to management and customers.
• Manage project budgets, variations, change orders and billing milestones to protect margins and cash flow.
• Customer Management
• Act as the single point of contact for customers, consultants, PMCs and EPC contractors throughout the project.
• Conduct kick-off meetings, progress reviews and site coordination meetings; maintain minutes and action trackers.
• Manage customer expectations, resolve technical and commercial issues promptly, and build long-term relationships for repeat business.
• Coordinate customer inspections, Factory Acceptance Tests (FAT) and witness tests.
• Ensure timely collection of payments and closure of punch points, handover documents and completion certificates.
• Drawing Document Approval
• Coordinate with the design team for preparation of GA drawings, SLDs, schematics, wiring diagrams, BOMs and cable schedules.
• Submit drawings and technical documents to customers/consultants, track comments and secure approvals within agreed timelines.
• Manage revision control and ensure only approved drawings are released to the plant for manufacturing.
• Prepare and submit QAP, test procedures, O M manuals and as-built drawings.
• Internal Plant Operations Coordination
• Coordinate with design, purchase, production, QA/QC, stores and dispatch teams to meet manufacturing and delivery schedules.
• Release approved drawings and BOMs to production and follow up on material availability and long-lead items (breakers, busbars, relays, enclosures).
• Monitor shop-floor progress, resolve bottlenecks and ensure in-house testing and quality checks are completed before dispatch.
• Plan logistics, packing and dispatch in line with site readiness.
• Site Execution, Testing Commissioning
• Travel to project sites to supervise installation, cable termination, testing and commissioning of panels.
• Manage site engineers, technicians and subcontractors; ensure adherence to safety (HSE) norms and statutory requirements.
• Coordinate pre-commissioning checks, IR / HV tests, relay testing, functional checks and integration with other systems (DG, UPS, BMS/EPMS).
• Close punch lists, obtain SAT sign-off and ensure smooth handover to the customer.
• Planning Risk Mitigation
• Identify technical, commercial, schedule and site risks early; maintain a risk register with mitigation and contingency plans.
• Anticipate delays in approvals, materials or site readiness and take corrective action proactively.
• Ensure contractual compliance, including LD clauses, warranties and scope boundaries.
• Conduct project close-out reviews and capture lessons learned for future projects.
Data Centre Project Experience (Beneficial) Candidates must have hands-on experience executing electrical panel projects for data centres, including:
• Main LT Panels (PCC/MCC), Power Distribution Units (PDUs), UPS input/output panels, AMF/synchronisation panels and busduct interfaces.
• Understanding of redundancy architectures (N, N+1, 2N) and Tier III / Tier IV design requirements.
• Working within fast-track schedules, strict quality documentation and multi-stakeholder environments (owner, consultant, PMC, EPC).
• Integrated System Testing (IST) and Level 1–5 commissioning processes. Required Qualifications Experience
• B.
E. / B.
Tech in Electrical Engineering.
• Minimum 5 years of experience in project management of SITC of LV/MV electrical panels.
• Proven track record of delivering at least one data centre project end to end.
• Sound knowledge of relevant standards – IEC 61439.
• Working knowledge of AutoCAD (reading/reviewing drawings), MS Project / Primavera and MS Office.
• PMP or equivalent project management certification will be an advantage. Key Skills Competencies
• Planning: Robust project planning, scheduling and cost control.
• Customer Handling: Confident, professional communication with customers and consultants.
• Coordination: Ability to align design, production and site teams toward common deadlines.
• Problem Solving: Quick, practical decision-making under site pressure.
• Leadership: Leading site teams and subcontractors safely and efficiently.
• Mobility: Willing to travel frequently and stay at project sites for extended periods. Key Performance Indicators
• On-time project delivery against agreed schedule.
• Drawing approval turnaround time.
• Project margin and budget adherence.
• Customer satisfaction and repeat orders.
• Timely billing and payment collection.
• Zero safety incidents at site.
📌 Project Manager (Bengaluru)
🏢 Switchgear and Control Technics Private Limited(SCTPL)
📍 Bengaluru